STC Valve Inc Logo Flow Control Valve Stainless Steel Push In Elbow Fitting Stainless Steel Compression Fitting Pneumatic Air Valve Bronze Two Way Process Valve Stainless Steel Manual Ball Valve Stainless Steel Air Actuated Ball Valve Manual Four Way Air Valve Air Filter Regulator Lubricator Combination Air Filter Regulator Lubricator Combination Contact Us
Support & Downloads
Home 1 Push In Fittings 2 Stainless Steel Fittings 3 Compr.&
Barb Fittings
4 Solenoid Valves 5 Process Valves 6 Manual
Ball Valves
7 Actuated Valves 8 Air Valves 9 Air Regulators 10 Air Cylinders Click Here
to Order

Call us at (650) 856-8833 or email us at Sales@StcValve.com.

Solenoid Valve Specifications and Dimensions: 2P160-250 & 2PO160-250 Series

Part No. Valve Picture Port Size (NPT) Voltage Electrical Connection Description Cv / Orifice Power Consumption Valve Symbol
2P160-1/2 1/2" 1 = 12VDC
2 = 24VDC

2A = 24VAC
3 = 110VAC
4 = 220VAC (50/60Hz)
D = DIN Service: Air, Liquid, Oil, Water
Direct Lift Diaphragm
Normally Closed
Two Way Diaphragm
PA Plastic Solenoid Valve
Temperature: 32 to 122°F (0 to 50°C) (with NBR Seal)
Pressure: Vacuum to 90PSI
Vacuum Reverse Flow Direction
H Class IP65, 100% ED Coil Duty
Voltage Tolerances: +10%-5% for DC, +10%-15% for AC
Cv = 4.8
Orifice = 16mm
12 to 20W
2P200-3/4 3/4" Cv = 7.6
Orifice = 20mm
2P250-1 1" Cv = 12
Orifice = 25mm
2PO160-1/2 1/2" 1 = 12VDC
2 = 24VDC

2A = 24VAC
3 = 110VAC
4 = 220VAC (50/60Hz)
D = DIN Service: Air, Liquid, Oil, Water
Direct Lift Diaphragm
Normally Open
Two Way Diaphragm
PA Plastic Solenoid Valve
Temperature: 32 to 122°F (0 to 50°C) (with NBR Seal)
Pressure: Vacuum to 90PSI
Vacuum Reverse Flow Direction
H Class IP65, 100% ED Coil Duty
Voltage Tolerances: +10%-5% for DC, +10%-15% for AC
Cv = 4.8
Orifice = 16mm
12 to 20W
2PO200-3/4 3/4" Cv = 7.6
Orifice = 20mm
2PO250-1 1" Cv = 12
Orifice = 25mm

2P160-250 Series 2/2 Direct Lift Diaphragm Normally Closed Solenoid Valve:
This valve is a two-way, normally closed, direct lift, zero differential solenoid valve. When the valve receives an electrical signal, a magnetic field is formed which attracts the plunger covering the main orifice to lift off, causing system pressure to drop. As system pressure on the top of the diaphragm is reduced, full system pressure on the other side of the diaphragm acts to lift the diaphragm away from the main orifice, which allows media to flow through the valve. Since the bleed orifice is dimensionally smaller than the pilot orifice, the system pressure cannot rebuild on the top of the diaphragm as long as the pilot orifice remains open.
When the valve is de-energized, it releases its hold on the plunger. Then the plunger forced by the spring drops and covers the main orifice. The system pressure builds up on the top of the diaphragm through the bleed orifice, forcing the diaphragm down until it covers the main orifice and stops media flow through the valve.


2PO160-250 Series 2/2 Direct Lift Diaphragm Normally Open Solenoid Valve:
To Close: When the valve is energized, the coil repels the plunger then the plunger covers the main orifice. The system pressure builds up on the top of the diaphragm/piston through the bleed orifice, forcing the diaphragm/piston down until it covers the main orifice and stops media flow through the valve. When the system pressure is 0PSI, the valve also can be operated.
To Open: When the valve is de-energized, the coil releases the plunger. The plunger uncovers the pilot orifice causing system pressure holding the diaphragm/piston closed to drop. As system pressure on the top of the diaphragm/piston is reduced, full system pressure on the opposite side of the diaphragm/piston acts to lift the diaphragm/piston away from the main orifice, which allows the full media flow through the valve. When the system pressure is 0PSI, the valve can be operated.


ALL standard valves are supplied with Continuous Duty Coils of the proper class of insulation for the service indicated on the valve. It is normal for the coil temperature may become hot after being energized for extended periods. Smoke or burning odor indicates excessive coil temperature and the power should be disconnected to the coil immediately.

CAUTION: Do not energize the solenoid coil when it is not installed onto the valve. It may cause it to overheat and create a fire hazard.

SERVICE LIFE: The service life of the solenoid valve depends on the operating conditions such as pressure, temperature, type of medium, and the voltage.

Electrical Coil Connections

2P Normally Closed

2PO Normally Open
Model: 2P160-250/2PO160-250 Series Solenoid Valve Dimensions
Model Port (NPT) Cv Orifice A B C D E F W (lb)
2P Series Normally Closed 2PO Series Normally Open 2P Series Normally Closed 2PO Series Normally Open
2P160-1/2
2PO160-1/2
1/2"4.816100113511151287436601
2P200-3/4
2PO200-3/4
3/4"7.62095108511151287036601
2P250-1
2PO250-1
1"1225105118651251388736601.2
Dimensions for Reference Use Only: Units in mm